Chilled Water System Basics - Chilled water systems work much the same way as direct expansion systems work. The exception is they use water in the coil rather than refrigerant. Technically speaking, water can be classified as a refrigerant. Chilled Water systems can be rather complex and many chilled water systems are found in commercial and industrial applications. There are some chilled water systems used in residential applications.
However, chilled water system in residential HVAC cooling system is extremely rare. A typical chiller uses the process of refrigeration to chill water in a chiller barrel. This water is pumped through chilled water piping throughout the building where it will pass through a coil. Air is passed over this coil and the heat exchange process takes place. The heat in the air is absorbed into the coils and then into the water. The water is pumped back to the chiller to have the heat removed. It then makes the trip back through the building and the coils all over again.
The chiller basically removes heat from the water. It is used as a refrigerant to remove heat from the building. The chilled water circulates through a chilled water loop and through coils located in air handlers. Chilled water systems include other HVAC equipment designed to exchange heat such as computer room central air conditioner. The chilled water absorbs the heat from the building. It then returns to the chiller where the chiller removes the heat from the water using the refrigeration process. Some chilled water loop arrangements are very complex while others are simple. Control of the chilled water from pressure to velocity, to volume, is up to the control system controlling the pumps and valve actuators in the system.
Chillers range in size from smaller than 5 tons all the way up to several hundred tons. Chillers can be found in residential applications, commercial buildings, and industrial process applications.
Many chillers have cooling towers where the heat removed in the chiller barrel is transferred to another barrel. It is the condenser barrel where the refrigerant is condensed and sent back to the evaporator barrel to remove the heat. The process is in reverse in the condenser barrel. The water absorbs heat from the refrigerant and allows it to condense.
The water is then transferred to a cooling tower where the heat in this water is removed to the atmosphere. Once the heat is removed from the water it is pumped back to the chiller barrel to absorb more heat from the refrigerant. Some chillers do not have a condenser barrel to remove the heat. The refrigerant is pumped into a condenser coil where a fan blows across the coil and removes the heat. These chillers are cheaper to purchase upfront but not as efficient to run as those with the condenser barrels. The upfront costs are less but the energy costs are more over the long run. One bonus to an air cooled chiller is that it does not require a cooling tower and therefore the maintenance costs associated with maintaining a cooling tower.
Chilled water systems provide comfort to mainly commercial buildings and are typically cheaper to operate than Direct Expansion (DX) systems. While many buildings have DX systems in the way of large rooftop units, the cost of installation is generally cheap for the DX systems because all that is required to install them is ductwork and electrical service to the unit. With chilled water systems, chilled water piping must be installed throughout the building and this can be far more expensive to install over the plain old DX rooftop units which supply conditioned air to a VAV system that has electric reheat in them.
To prevent water from flooding all over the floor and in the space where the relocation of the chilled water piping was necessary, a piping freeze machine was used to stop the flow of water so that the chilled water pipe could be cut and re-soldered to accommodate its new location. Pipe freezing also allows the new piping to be soldered into place because it prevents water flow inside the pipe. Copper pipe cannot be soldered if it has water inside it. For years plumbers and HVAC technicians used bread or a mechanical stop to keep water out of the pipe so it can be soldered. The bread rolled into a ball and inserted into the pipe, would prevent the water from forming around the solder joint allowing it to be soldered.
Author:
Mr. Richard Lee
Phone/WhatsApp:
+8613605314726
Mag-email sa supplier na ito
Author:
Mr. Richard Lee
Phone/WhatsApp:
+8613605314726
April 02, 2021
Pahayag ng Pagkapribado: Napakahalaga sa amin ng iyong privacy. Nangako ang aming kumpanya na huwag ibunyag ang iyong personal na impormasyon sa anumang paglawak sa iyong tahasang mga pahintulot.
Punan ang karagdagang impormasyon upang makapag -ugnay sa iyo nang mas mabilis
Pahayag ng Pagkapribado: Napakahalaga sa amin ng iyong privacy. Nangako ang aming kumpanya na huwag ibunyag ang iyong personal na impormasyon sa anumang paglawak sa iyong tahasang mga pahintulot.